The performance of steel-concrete composite full strength joints endowed with concrete filled tubes, designed with a multi-objective methodology dealing with seismic actions followed by fire is presented in this paper. In detail, instead of a traditional single-objective design where fire safety and seismic safety are independently achieved and the sequence of seismic and fire loading are not taken into account, the proposed design approach guarantees: (i) both seismic safety and fire safety with regard to accidental actions; (ii) fire safety for at least 15 min fire exposure on a joint characterised by stiffness deterioration and strength degradation due to seismic loading. In order to achieve the multi-objective design, full strength beam-to-composite tubular column joints were designed by means of the component method of Eurocode 4 Part 1-1 and Eurocode 3 Part 1-8, while Eurocode 4 Part 1-2 was considered for fire design. Moreover, to face a seismic-induced fire, they were enhanced with specific joint components which will be detailed. Both the experimental programme and the results provided by seismic tests, pre-damaged tests and fire tests carried out on beam-to-column joints are presented and discussed. The results demonstrate their adequacy in terms of design and performance. Moreover, non-linear numerical simulations clearly show that these joints can be deemed adequate for moment resisting frames of medium ductility class characterised by a behaviour factor of about 4. (C) 2011 Elsevier Ltd. All rights reserved.

Post-earthquake fire and seismic performance of welded steel-concrete composite beam-to-column joints

PUCINOTTI, RAFFAELE;
2011-01-01

Abstract

The performance of steel-concrete composite full strength joints endowed with concrete filled tubes, designed with a multi-objective methodology dealing with seismic actions followed by fire is presented in this paper. In detail, instead of a traditional single-objective design where fire safety and seismic safety are independently achieved and the sequence of seismic and fire loading are not taken into account, the proposed design approach guarantees: (i) both seismic safety and fire safety with regard to accidental actions; (ii) fire safety for at least 15 min fire exposure on a joint characterised by stiffness deterioration and strength degradation due to seismic loading. In order to achieve the multi-objective design, full strength beam-to-composite tubular column joints were designed by means of the component method of Eurocode 4 Part 1-1 and Eurocode 3 Part 1-8, while Eurocode 4 Part 1-2 was considered for fire design. Moreover, to face a seismic-induced fire, they were enhanced with specific joint components which will be detailed. Both the experimental programme and the results provided by seismic tests, pre-damaged tests and fire tests carried out on beam-to-column joints are presented and discussed. The results demonstrate their adequacy in terms of design and performance. Moreover, non-linear numerical simulations clearly show that these joints can be deemed adequate for moment resisting frames of medium ductility class characterised by a behaviour factor of about 4. (C) 2011 Elsevier Ltd. All rights reserved.
File in questo prodotto:
File Dimensione Formato  
Pucinotti et al. JCSR 2011.pdf

non disponibili

Tipologia: Versione Editoriale (PDF)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 4.35 MB
Formato Adobe PDF
4.35 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12318/200
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 51
  • ???jsp.display-item.citation.isi??? 43
social impact