An array of silicon interferometric temperature micro-sensors is presented based on the thermo-optic effect. These sensors, consisting of planar Fabry-Perot cavities of various length, realised on the same chip, have been fabricated adopting standard microelectronic technologies. This permits the full integration of the sensors with other active silicon opto- and electronic devices. Moreover, the possibility of realising on the same chip sensors with lengths ranging from microns to millimetres allows the use of the noise-immune fringe counting technique. By monitoring the output of all the interferometers at the same time, in fact, the direction of changing and a rough estimation of the temperature is given by the shorter cavities, while a more and more accurate measurement is furnished by the longer cavities

Temperature monitoring with a fully integrable on chip interferometric silicon micro-sensor based on the thermo-optic effect / G, Cocorullo; F. G., Della Corte; M, Iodice; I, Rendina; Pm, Sarro; DELLA CORTE, Francesco Giuseppe. - 3:(1996), pp. 1321-1323. (Intervento presentato al convegno Electrotechnical Conference, 1996. MELECON '96., 8th Mediterranean) [10.1109/MELCON.1996.551190].

Temperature monitoring with a fully integrable on chip interferometric silicon micro-sensor based on the thermo-optic effect

DELLA CORTE, Francesco Giuseppe
1996-01-01

Abstract

An array of silicon interferometric temperature micro-sensors is presented based on the thermo-optic effect. These sensors, consisting of planar Fabry-Perot cavities of various length, realised on the same chip, have been fabricated adopting standard microelectronic technologies. This permits the full integration of the sensors with other active silicon opto- and electronic devices. Moreover, the possibility of realising on the same chip sensors with lengths ranging from microns to millimetres allows the use of the noise-immune fringe counting technique. By monitoring the output of all the interferometers at the same time, in fact, the direction of changing and a rough estimation of the temperature is given by the shorter cavities, while a more and more accurate measurement is furnished by the longer cavities
1996
0-7803-3109-5
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12318/21117
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact