The main aim of this work is to evaluate how the use of an active protection method, consisting in an improved forced longitudinal ventilation system, can determine a positive impact on heat extraction and people evacuation time in a tunnel fire scenario, by considering a case study which simulations are based on a real gallery.

Tunnel fire active protection: improving ventilation system

Pietrafesa, Matilde;
2019

Abstract

The main aim of this work is to evaluate how the use of an active protection method, consisting in an improved forced longitudinal ventilation system, can determine a positive impact on heat extraction and people evacuation time in a tunnel fire scenario, by considering a case study which simulations are based on a real gallery.