The main aim of this work is to evaluate how the use of an active protection method, consisting in an improved forced longitudinal ventilation system, can determine a positive impact on heat extraction and people evacuation time in a tunnel fire scenario, by considering a case study which simulations are based on a real gallery.

Tunnel fire active protection: improving ventilation system / Cirrincione, Laura; Scaccianoce, Gianluca; Scrudato, Michael; Pietrafesa, Matilde; Rizzo, Gianfranco. - In: JOURNAL OF PHYSICS. CONFERENCE SERIES. - ISSN 1742-6588. - 1224:1(2019), pp. 1-11. [10.1088/1742-6596/1224/1/012005]

Tunnel fire active protection: improving ventilation system

Pietrafesa, Matilde;
2019-01-01

Abstract

The main aim of this work is to evaluate how the use of an active protection method, consisting in an improved forced longitudinal ventilation system, can determine a positive impact on heat extraction and people evacuation time in a tunnel fire scenario, by considering a case study which simulations are based on a real gallery.
File in questo prodotto:
File Dimensione Formato  
Cirrincione_2019_Tunnel_editor.pdf

accesso aperto

Descrizione: Versione editoriale
Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 1.37 MB
Formato Adobe PDF
1.37 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.