The occurrence of aflatoxin M1 in 69 milk samples collected in a south region of Italy in 2016 was evaluated. The samples were analysed using an automated method based on online SPE coupled with UHPLC tandem mass spectrometry. After a salt induced liquid–liquid extraction with acetonitrile to remove protein from milk, the extract was diluted with water and analysed using an automated online SPE MS/MS method. Among the analysed samples no one had AFM1 higher than the legally allowable limits whereas 71.4% of the other analysed samples were above the LOD of the method. The highest contamination level of AFM1 was found in pasteurised milk (44.39 ng kg−1). The results show the worrying and widespread of AFM1 contamination, highlighting the necessity of monitoring studies in order to evaluate the reduction of the maximum legal limit.
Occurrence of aflatoxin M1 in milk samples from Italy analysed by online-SPE UHPLC-MS/MS / Campone, L.; Piccinelli, A. L.; Celano, R.; Pagano, I.; DI SANZO, Rosa; Carabetta, S.; Russo, Mariateresa; Rastrelli, L.. - In: NATURAL PRODUCT RESEARCH. - ISSN 1478-6419. - 32:15(2018), pp. 1803-1808. [10.1080/14786419.2017.1402327]
Occurrence of aflatoxin M1 in milk samples from Italy analysed by online-SPE UHPLC-MS/MS
Di Sanzo Rosa;Russo Mariateresa;
2018-01-01
Abstract
The occurrence of aflatoxin M1 in 69 milk samples collected in a south region of Italy in 2016 was evaluated. The samples were analysed using an automated method based on online SPE coupled with UHPLC tandem mass spectrometry. After a salt induced liquid–liquid extraction with acetonitrile to remove protein from milk, the extract was diluted with water and analysed using an automated online SPE MS/MS method. Among the analysed samples no one had AFM1 higher than the legally allowable limits whereas 71.4% of the other analysed samples were above the LOD of the method. The highest contamination level of AFM1 was found in pasteurised milk (44.39 ng kg−1). The results show the worrying and widespread of AFM1 contamination, highlighting the necessity of monitoring studies in order to evaluate the reduction of the maximum legal limit.File | Dimensione | Formato | |
---|---|---|---|
Campone_2017JNPR_ Occurrence_postprint.pdf
Open Access dal 18/11/2018
Descrizione: Post print autore
Tipologia:
Documento in Post-print
Licenza:
Creative commons
Dimensione
272.43 kB
Formato
Adobe PDF
|
272.43 kB | Adobe PDF | Visualizza/Apri |
Campone_2017JNPR_ Occurrence_editorial.pdf
non disponibili
Tipologia:
Versione Editoriale (PDF)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
804.65 kB
Formato
Adobe PDF
|
804.65 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.